- Series :
- Part Status :
- Operating Temperature :
- Connector Type :
- Voltage Rating :
- Flat Flex Type :
- FFC, FCB Thickness :
- Applied Filters :
120 products
IMAGE | PART NO. | PRICE (reference only) | QUANTITY | STOCK | Mfr. | DESCRIPTION | Series | Part Status | Packaging | Operating Temperature | Features | Material Flammability Rating | Connector Type | Number of Positions | Number of Rows | Pitch | Voltage Rating | Housing Material | Flat Flex Type | FFC, FCB Thickness | Locking Feature | |
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
|
GET PRICE |
79,360
One step to sell excess stocks.Or submit Qty to get quotes
|
TE Connectivity AMP Connectors | CONN FFC RCPT HSG 26POS 2.54MM | - | Obsolete | Bulk | -65°C ~ 105°C | Positions Stamped | UL94 V-0 | Housing for Female Contacts | 26 | 2 | 0.100" (2.54mm) | 300V | Polyamide (PA), Nylon, Glass Filled | FFC, Discrete Wire | 0.015mm | Detent Lock | |||
|
GET PRICE |
38,760
One step to sell excess stocks.Or submit Qty to get quotes
|
TE Connectivity AMP Connectors | CONN FFC RCPT HSG 36POS 1.27MM | AMPMODU System 50 | Obsolete | Bulk | -55°C ~ 105°C | - | UL94 V-0 | Housing for Female Contacts | 36 | 1 | 0.050" (1.27mm) | 100V | Polyester | FFC | 0.05-0.08mm | Detent Lock | |||
|
GET PRICE |
49,000
One step to sell excess stocks.Or submit Qty to get quotes
|
TE Connectivity AMP Connectors | CONN FFC RCPT HSG 4POS 1.27MM | AMPMODU System 50 | Obsolete | Bulk | -55°C ~ 105°C | - | UL94 V-0 | Housing for Female Contacts | 4 | 1 | 0.050" (1.27mm) | 100V | Polyester | FFC | 0.05-0.08mm | Detent Lock | |||
|
GET PRICE |
58,360
One step to sell excess stocks.Or submit Qty to get quotes
|
TE Connectivity AMP Connectors | CONN FFC RCPT HSG 6POS 2.54MM | - | Obsolete | Bulk | -65°C ~ 105°C | Positions Stamped | UL94 V-0 | Housing for Female Contacts | 6 | 2 | 0.100" (2.54mm) | 300V | Polyamide (PA), Nylon, Glass Filled | FFC, Discrete Wire | 0.015mm | Detent Lock | |||
|
25,280
One step to sell excess stocks.Or submit Qty to get quotes
|
TE Connectivity AMP Connectors | CONN FFC RCPT HSG 60POS 2.54MM | - | Active | Bulk | -65°C ~ 105°C | Flange, Positions Stamped | UL94 V-0 | Housing for Female Contacts | 60 | 2 | 0.100" (2.54mm) | 300V | Polyamide (PA), Nylon, Glass Filled | FFC, Discrete Wire | 0.015mm | Detent Lock | ||||
|
33,820
One step to sell excess stocks.Or submit Qty to get quotes
|
TE Connectivity AMP Connectors | CONN FFC RCPT HSG 44POS 2.54MM | - | Active | Bulk | -65°C ~ 105°C | Flange, Positions Stamped | UL94 V-0 | Housing for Female Contacts | 44 | 2 | 0.100" (2.54mm) | 300V | Polyamide (PA), Nylon, Glass Filled | FFC, Discrete Wire | 0.015mm | Detent Lock | ||||
|
38,580
One step to sell excess stocks.Or submit Qty to get quotes
|
TE Connectivity AMP Connectors | CONN FFC RCPT HSG 70POS 2.54MM | - | Active | Bulk | -65°C ~ 105°C | Flange, Positions Stamped | UL94 V-0 | Housing for Female Contacts | 70 | 2 | 0.100" (2.54mm) | 300V | Polyamide (PA), Nylon, Glass Filled | FFC, Discrete Wire | 0.015mm | Detent Lock | ||||
|
79,960
One step to sell excess stocks.Or submit Qty to get quotes
|
TE Connectivity AMP Connectors | CONN FFC RCPT HSG 40POS 2.54MM | - | Active | Bulk | -65°C ~ 105°C | Flange, Positions Stamped | UL94 V-0 | Housing for Female Contacts | 40 | 2 | 0.100" (2.54mm) | 300V | Polyamide (PA), Nylon, Glass Filled | FFC, Discrete Wire | 0.015mm | Detent Lock | ||||
|
43,860
One step to sell excess stocks.Or submit Qty to get quotes
|
TE Connectivity AMP Connectors | CONN FFC PIN HSG 13POS 2.54MM | - | Active | Bulk | -65°C ~ 105°C | - | UL94 V-0 | Housing for Male Contacts | 13 | 1 | 0.100" (2.54mm) | 300V | Thermoplastic | FFC, Discrete Wire | 0.05-0.13mm | Detent Lock | ||||
|
68,880
One step to sell excess stocks.Or submit Qty to get quotes
|
TE Connectivity AMP Connectors | CONN FFC RCPT HSG 24POS 2.54MM | - | Active | Bulk | -65°C ~ 105°C | Flange, Positions Stamped | UL94 V-0 | Housing for Female Contacts | 24 | 2 | 0.100" (2.54mm) | 300V | Polyamide (PA), Nylon, Glass Filled | FFC, Discrete Wire | 0.015mm | Detent Lock | ||||
|
20,760
One step to sell excess stocks.Or submit Qty to get quotes
|
TE Connectivity AMP Connectors | CONN FFC RCPT HSG 58POS 2.54MM | - | Active | Bulk | -65°C ~ 105°C | Flange, Positions Stamped | UL94 V-0 | Housing for Female Contacts | 58 | 2 | 0.100" (2.54mm) | 300V | Polyamide (PA), Nylon, Glass Filled | FFC, Discrete Wire | 0.015mm | Detent Lock | ||||
|
24,500
One step to sell excess stocks.Or submit Qty to get quotes
|
TE Connectivity AMP Connectors | CONN FFC PIN HSG 40POS 2.54MM | - | Active | Bulk | -65°C ~ 105°C | Flange, Positions Stamped | UL94 V-0 | Housing for Male Contacts | 40 | 2 | 0.100" (2.54mm) | 300V | Polyamide (PA), Nylon, Glass Filled | FFC, Discrete Wire | 0.015mm | Detent Lock | ||||
|
51,980
One step to sell excess stocks.Or submit Qty to get quotes
|
TE Connectivity AMP Connectors | CONN FFC PIN HSG 38POS 2.54MM | - | Active | Bulk | -65°C ~ 105°C | Flange, Positions Stamped | UL94 V-0 | Housing for Male Contacts | 38 | 2 | 0.100" (2.54mm) | 300V | Polyamide (PA), Nylon, Glass Filled | FFC, Discrete Wire | 0.015mm | Detent Lock | ||||
|
48,600
One step to sell excess stocks.Or submit Qty to get quotes
|
TE Connectivity AMP Connectors | CONN FFC PIN HSG 6POS 2.54MM | - | Active | Bulk | -65°C ~ 105°C | Flange, Positions Stamped | UL94 V-0 | Housing for Male Contacts | 6 | 2 | 0.100" (2.54mm) | 300V | Polyamide (PA), Nylon, Glass Filled | FFC, Discrete Wire | 0.015mm | Detent Lock | ||||
|
63,020
One step to sell excess stocks.Or submit Qty to get quotes
|
TE Connectivity AMP Connectors | CONN FFC PIN HSG 24POS 2.54MM | - | Active | Bulk | -65°C ~ 105°C | Flange, Positions Stamped | UL94 V-0 | Housing for Male Contacts | 24 | 2 | 0.100" (2.54mm) | 300V | Polyamide (PA), Nylon, Glass Filled | FFC, Discrete Wire | 0.015mm | Detent Lock | ||||
|
29,920
One step to sell excess stocks.Or submit Qty to get quotes
|
TE Connectivity AMP Connectors | CONN FFC RCPT HSG 38POS 2.54MM | - | Active | Bulk | -65°C ~ 105°C | Flange, Positions Stamped | UL94 V-0 | Housing for Female Contacts | 38 | 2 | 0.100" (2.54mm) | 300V | Polyamide (PA), Nylon, Glass Filled | FFC, Discrete Wire | 0.015mm | Detent Lock | ||||
|
29,040
One step to sell excess stocks.Or submit Qty to get quotes
|
TE Connectivity AMP Connectors | CONN FFC PIN HSG 26POS 2.54MM | - | Active | Bulk | -65°C ~ 105°C | Flange, Positions Stamped | UL94 V-0 | Housing for Male Contacts | 26 | 2 | 0.100" (2.54mm) | 300V | Polyamide (PA), Nylon, Glass Filled | FFC, Discrete Wire | 0.015mm | Detent Lock | ||||
|
15,400
One step to sell excess stocks.Or submit Qty to get quotes
|
TE Connectivity AMP Connectors | CONN FFC PIN HSG 18POS 2.54MM | - | Active | Bulk | -65°C ~ 105°C | Positions Stamped | UL94 V-0 | Housing for Male Contacts | 18 | 2 | 0.100" (2.54mm) | 300V | Polyamide (PA), Nylon, Glass Filled | FFC, Discrete Wire | 0.015mm | Detent Lock | ||||
|
24,120
One step to sell excess stocks.Or submit Qty to get quotes
|
TE Connectivity AMP Connectors | CONN FFC PIN HSG 16POS 2.54MM | - | Active | Bulk | -65°C ~ 105°C | Flange, Positions Stamped | UL94 V-0 | Housing for Male Contacts | 16 | 2 | 0.100" (2.54mm) | 300V | Polyamide (PA), Nylon, Glass Filled | FFC, Discrete Wire | 0.015mm | Detent Lock | ||||
|
20,780
One step to sell excess stocks.Or submit Qty to get quotes
|
TE Connectivity AMP Connectors | CONN FFC RCPT HSG 40POS 2.54MM | - | Active | Bulk | -65°C ~ 105°C | Positions Stamped | UL94 V-0 | Housing for Female Contacts | 40 | 2 | 0.100" (2.54mm) | 300V | Polyamide (PA), Nylon, Glass Filled | FFC, Discrete Wire | 0.015mm | Detent Lock | ||||
|
20,400
One step to sell excess stocks.Or submit Qty to get quotes
|
TE Connectivity AMP Connectors | CONN FFC RCPT HSG 32POS 2.54MM | - | Active | Bulk | -65°C ~ 105°C | - | UL94 V-0 | Housing for Female Contacts | 32 | 1 | 0.100" (2.54mm) | 300V | Polybutylene Terephthalate (PBT), Glass Filled | FFC | 0.05-0.13mm | Detent Lock | ||||
|
13,580
One step to sell excess stocks.Or submit Qty to get quotes
|
TE Connectivity AMP Connectors | CONN FFC RCPT HSG 35POS 2.54MM | - | Active | Bulk | -65°C ~ 105°C | - | UL94 V-0 | Housing for Female Contacts | 35 | 1 | 0.100" (2.54mm) | 300V | Polybutylene Terephthalate (PBT), Glass Filled | FFC | 0.05-0.13mm | Detent Lock | ||||
|
67,700
One step to sell excess stocks.Or submit Qty to get quotes
|
TE Connectivity AMP Connectors | CONN FFC RCPT HSG 20POS 2.54MM | - | Active | Bulk | -65°C ~ 105°C | Flange, Positions Stamped | UL94 V-0 | Housing for Female Contacts | 20 | 2 | 0.100" (2.54mm) | 300V | Polyamide (PA), Nylon, Glass Filled | FFC, Discrete Wire | 0.015mm | Detent Lock | ||||
|
30,940
One step to sell excess stocks.Or submit Qty to get quotes
|
TE Connectivity AMP Connectors | CONN FFC RCPT HSG 40POS 2.54MM | - | Active | Bulk | -65°C ~ 105°C | Positions Stamped | UL94 V-0 | Housing for Female Contacts | 40 | 2 | 0.100" (2.54mm) | 300V | Polyamide (PA), Nylon, Glass Filled | FFC, Discrete Wire | 0.015mm | Detent Lock | ||||
|
15,720
One step to sell excess stocks.Or submit Qty to get quotes
|
TE Connectivity AMP Connectors | CONN FFC RCPT HSG 18POS 2.54MM | - | Active | Bulk | -65°C ~ 105°C | Flange, Positions Stamped | UL94 V-0 | Housing for Female Contacts | 18 | 2 | 0.100" (2.54mm) | 300V | Polyamide (PA), Nylon, Glass Filled | FFC, Discrete Wire | 0.015mm | Detent Lock | ||||
|
27,840
One step to sell excess stocks.Or submit Qty to get quotes
|
TE Connectivity AMP Connectors | CONN FFC RCPT HSG 28POS 2.54MM | - | Active | Bulk | -65°C ~ 105°C | Flange, Positions Stamped | UL94 V-0 | Housing for Female Contacts | 28 | 2 | 0.100" (2.54mm) | 300V | Polyamide (PA), Nylon, Glass Filled | FFC, Discrete Wire | 0.015mm | Detent Lock | ||||
|
51,720
One step to sell excess stocks.Or submit Qty to get quotes
|
TE Connectivity AMP Connectors | CONN FFC RCPT HSG 50POS 2.54MM | - | Active | Bulk | -65°C ~ 105°C | Positions Stamped | UL94 V-0 | Housing for Female Contacts | 50 | 2 | 0.100" (2.54mm) | 300V | Polyamide (PA), Nylon, Glass Filled | FFC, Discrete Wire | 0.015mm | Detent Lock | ||||
|
38,120
One step to sell excess stocks.Or submit Qty to get quotes
|
TE Connectivity AMP Connectors | CONN FFC PIN HSG 6POS 2.54MM | - | Active | Bulk | -65°C ~ 105°C | Positions Stamped | UL94 V-0 | Housing for Male Contacts | 6 | 2 | 0.100" (2.54mm) | 300V | Polyamide (PA), Nylon, Glass Filled | FFC, Discrete Wire | 0.015mm | Detent Lock | ||||
|
40,240
One step to sell excess stocks.Or submit Qty to get quotes
|
TE Connectivity AMP Connectors | CONN FFC RCPT HSG 10POS 2.54MM | - | Active | Bulk | -65°C ~ 105°C | Positions Stamped | UL94 V-0 | Housing for Female Contacts | 10 | 2 | 0.100" (2.54mm) | 300V | Polyamide (PA), Nylon, Glass Filled | FFC, Discrete Wire | 0.015mm | Detent Lock | ||||
|
61,100
One step to sell excess stocks.Or submit Qty to get quotes
|
TE Connectivity AMP Connectors | CONN FFC RCPT HSG 66POS 2.54MM | - | Active | Bulk | -65°C ~ 105°C | Flange, Positions Stamped | UL94 V-0 | Housing for Female Contacts | 66 | 2 | 0.100" (2.54mm) | 300V | Polyamide (PA), Nylon, Glass Filled | FFC, Discrete Wire | 0.015mm | Detent Lock |